Hose Heats But Heats Slower Than Usual Or Hose Does Not Reach Temperature

To avoid serious injury follow all warnings and instructions in the manual. Wear appropriate personal protective equipment.

  • Relocate hoses to a warmer area or recirculate heated fluid through the hose.
  • Check FTS. See Repair Fluid Temperature Sensor (FTS), in manual.
  • Verify line voltage. Low line voltage significantly reduces power available to the hose heat system, affecting longer hose lengths.
  • Match tap setting on transformer to hose length being used.