XM/PFP Software Change History

The Version History of XM and XM PFP Software is listed below.  The software currently installed on a system can be found by navigating to the Software Versions screen.  Details on this screen can be found in Appendix A of XM operation instruction manual 312359 or XM PFP operation instruction manual 3A2776 XM and XM PFP systems should match one of the following system versions.

Some XM systems may use an older version of software from token 16A265. For information on this software see, "XM - Software Version History", below. For more information on updating from this software, see "XM - Updating to 17E110 software".

Some XM PFP systems may use an older version of software from token 16P644. For information on this software see, "XM PFP - Software Version History", below.
Graco recommends that systems be updated to the newest version of software to allow use of all new features.

If upgrade to newer software version is desired, order the appropriate "Software Upgrade Token" as listed below.  This Upgrade Token is used to upgrade software on all of the system components per the procedure described in the XM repair instruction manual 313289 or XM PFP repair instruction manual 3A2989.

NOTE: Upgrading software will clear all USB data (i.e. pump cycles, material volume, etc.)  It is recommended that a full USB download be completed before upgrading software.

Software Upgrade Token 17E110 Series H

  • Display: 17C517 version 1.07.003
  • Advanced Fluid Control 17C961 version 1.07.001
  • USB: 17E067 version 1.02.001
  • USB Configuration: 17D027 version 1.02.001
  • Fluid Control Cube: 17C518 version 1.05.001
  • High Power Temperature Control: 15M871 version 1.07.005
  • Temperature Control: 17C620 version 1.02.001
  • Communications Gateway Module: 15U193 version 2.06.004
  • Updated method of triggering DKxX alarms

Software Upgrade Token 17E110 Series G

  • Display: 17C517 version 1.07.003
  • Advanced Fluid Control 17C961 version 1.06.011
  • USB: 17E067 version 1.02.001
  • USB Configuration: 17D027 version 1.02.001
  • Fluid Control Cube: 17C518 version 1.05.001
  • High Power Temperature Control: 15M871 version 1.07.005
  • Temperature Control: 17C620 version 1.02.001
  • Communications Gateway Module: 15U193 version 2.06.004
  • Custom pump sizes now use pump volume instead of effective area
  • Supports valve reed switch assembly 273274 (Note: This software version or newer is required with 273274)

Software Upgrade Token 17E110 Series F

  • Display: 17C517 version 1.06.001
  • Advanced Fluid Control 17C961 version 1.05.003
  • USB: 17E067 version 1.02.001
  • USB Configuration: 17D027 version 1.02.001
  • Fluid Control Cube: 17C518 version 1.04.001
  • High Power Temperature Control: 15M871 version 1.07.005
  • Temperature Control: 17C620 version 1.02.001
  • Changed tank level sensor defaults (XM PFP only)

Software Upgrade Token 17E110 Series E 

  • Display: 17C517 version 1.06.001
  • Advanced Fluid Control 17C961 version 1.05.003
  • USB: 17E067 version 1.02.001
  • USB Configuration: 17D027 version 1.02.001
  • Fluid Control Cube: 17C518 version 1.03.001
  • High Power Temperature Control: 15M871 version 1.07.005
  • Temperature Control: 17C620 version 1.02.001
  • Supports use of Communications Gateway Modules for XM ordinary location systems (see manual 3A5278A)
  • Increased trigger level of high pressure B alarm (P4BX)

Software Upgrade Token: 17E110 Series D

  • Display: 17C517 version 1.05.002
  • Advanced Fluid Control: 17C961 version 1.04.002
  • USB: 17E067 version 1.02.001
  • USB Configuration: 17D027 version 1.02.001
  • Fluid Control Cube: 17C518 version 1.03.001
  • High Power Temperature Control: 15M871 version 1.07.005
  • Temperature Control: 17C620 version 1.02.001
  • For USB logs, weight usage available in kg.

Software Upgrade Token: 17E110 Series C

  • Display: 17C517 version 1.04.001
  • Advanced Fluid Control: 17C961 version 1.03.001
  • USB: 17E067 version 1.01.001
  • USB Configuration: 17D027 version 1.01.001
  • Fluid Control Cube: 17C518 version 1.02.003
  • High Power Temperature Control: 15M871 version 1.07.005
  • Temperature Control: 17C620 version 1.02.001
  • Initial Release.

All System Versions listed below this are considered obsolete and are historical information.

Software Upgrade Token: 16A265 Series F

  • Display: 15R373 version 2.03.001
  • Fluid Control: 15R375 version 2.02.001
  • USB: 15W201 version 1.11.011
  • USB Configuration: 16A201 version 2.01.001
  • Compatibility with updated USB module due to electronic component obsolescence.

Software Upgrade Token: 16A265 Series E

  • Display: 15R373 version 2.02.001
  • Fluid Control: 15R375 version 2.01.001
  • USB: 15W201 version 1.10.001
  • USB Configuration: 16A201 version 2.01.001
  • Improve compatibility with USB drives.

 

Software Upgrade Token: 16A265 Series D

  • Display: 15R373 version 2.02.001
  • Fluid Control: 15R375 version 2.01.001
  • USB: 15W201 version 1.09.002
  • USB Configuration: 16A201 version 2.01.001
  • Improved display module contrast.

Software Upgrade Token: 16A265 Series C

  • Display: 15R373 version 2.01.001
  • Fluid Control: 15R375 version 2.01.001
  • USB: 15W201 version 1.09.002
  • USB Configuration: 16A201 version 2.01.001
  • The system ratio performance has been improved.
  • System response to B fluid restriction changes,  and flow rate changes has been improved.
  • System performance during air motor icing has been improved, and pressure imbalance caused by motor icing advisory (P9A, P9B) was added.
  • The Ratio Mode display screen has been significantly updated and includes dosing size and flow rate information.
  • The Alarm Information screen has been updated with new diagnostic information, including supply voltages, dose sizes, reed switch sensor state and linear position..
  • Air motor reed switch missing advisory (DLA, DLB) was added.
  • Air motor linear sensor jump advisory (DMA, DMB) was added.
  • Dosing size A advisory (B3A) and Alarm (B4A) was added.
  • Enabling the Fast Dosing checkbox will lower the Dosing Size A advisory from 35 cc to 20 cc,  and alarm from 45 cc to 30 cc. The software will attempt to hold the dosing sizes below the advisory level. This is used for faster-setting materials.
  • The dosing valves can now operate faster and provide smaller doses for better mixing.
  • USB download depth units reduced from days to hours.
  • Advisories will not give audible alarm and jump to Alarm Information screen (except Pot Life N4D).
  • The USB Spray and Data logs have been updated with much more information and commands, and the Command log has been eliminated.

Software Upgrade Token: 16A265 Series B

  • Display: 15R373 version 1.02.002
  • Fluid Control: 15R375 version 1.03.001
  • USB: 15W201 version 1.08.004
  • USB Configuration: 16A201 version 1.03.001

 

  • Changed overdose timeout error REC so it only works in Spray mode.
  • Added support for 16 Mbytes and 32 Mbytes USB memory.
  • Added power supply or alternator supply voltage to USB spray log.
  • Changed USB data log so it records every 2 minutes.
  • Renamed all USB logs.

Software Upgrade Token: 16A265 Series B

  • Display: 15R373 version 1.02.002
  • Fluid Control: 15R375 version 1.02.004
  • USB: 15W201 version 1.06.003
  • USB Configuration: 16A201 version 1.02.001
  • Initial Release.

Software Upgrade Token: 16P644 Series D

  • Display: 16P022 version 1.02.001
  • Advanced Fluid Control: 16P641 version 1.02.001
  • USB: 15W201 version 1.11.011
  • USB Configuration: 16P642 version 1.02.001
  • Fluid Control Cube: 19P023 version 1.03.001
  • High Power Temperature Control: 15M871 version 1.07.005
  • Compatibility with updated USB module due to electronic component obsolescence.

Software Upgrade Token: 16P644 Series C

  • Display: 16P022 version 1.02.001
  • Advanced Fluid Control: 16P641 version 1.02.001
  • USB: 15W201 version 1.10.001
  • USB Configuration: 16P642 version 1.02.001
  • Fluid Control Cube: 19P023 version 1.03.001
  • High Power Temperature Control: 15M871 version 1.07.005
  • Upgraded USB Cube software. Improved log file writes to external USB flash drive
  • Lowered the heater over-current alarm so they match the circuit breaker trip levels
  • Lowered the heater control range above the setpoint to 14.4 degrees F.
  • Improved signal noise immunity when actual temps above the heater setpoint

Software Upgrade Token: 16P644 Series B

  • Display: 16P022 version 1.02.001
  • Advanced Fluid Control: 16P641 version 1.02.001
  • USB: 15W201 version 1.09.002
  • USB Configuration: 16P642 version 1.02.001
  • Fluid Control Cube: 19P023 version 1.02.001
  • High Power Temperature Control: 15M871 version 1.07.005
  • Initial Release.