R4D0-A : High Ratio Alarm

To avoid serious injury follow all warnings and instructions in the manual. Wear appropriate personal protective equipment.

Re-calibrate the machine.

Check the material supply.

The flow could be turned down, or a larger sized hose could be used for the catalyst.

Run machine, until machine status states "OK".