T2D0 : Low Temperature Melter

To avoid serious injury follow all warnings and instructions in the manual. Wear appropriate personal protective equipment.

  • Verify system is operating within meltrate specifications. Consider incoming voltage and breaker setting.
  • Verify that the fill system (vacuum) is operating correctly. If the level of material in the melter gets too low and a large amount of cold material enters the melter, can cause the temperature to drop significantly.
  • With the system on and not dispensing verify that the temperature is properly controlled to the setpoint. If system cannot control temperature, verify the RTD is seated inside the melter.
  • Replace RTD if RTD was seated properly and system cannot control temperature.
  • Faulty melter heater(s). Check heater resistance and resistance to ground. Replace faulty heater(s).