E-8: Dose Time B Alarm

To avoid serious injury follow all warnings and instructions in the manual. Wear appropriate personal protective equipment.

Gun trigger input is active (AFS or Integration) and fewer than 31 B meter pulses were detected during the dose time selected.

 Increase flow rate.

  • To check meter sensor operation, remove meter cap to expose sensor. Pass a ferrous metal tool in front of the sensor. 
  • If there is a meter or cable failure, you will see a large difference between the amount of fluid dispensed and the flow meter volume displayed by the EasyKey. Clean or repair meter as necessary. Also see meter manual 308778. 
  • Follow Meter Calibration procedure, in manual. 

See E-3: RATIO HIGH ALARM and E-4: RATIO LOW ALARM.

Turn on the supply pump.

Check the air lines for leaks and repair.

Clean or replace air flow switch.