DE03 : Leak Detected Pump
To avoid serious injury follow all warnings and instructions in the manual. Wear appropriate personal protective equipment.
- Make sure the pump and down stream color line are loaded with material.
- Determine if leak is external or internal by visually inspecting the system for fluid leakage.
- Fix all loose or worn hoses, fittings, and seals. Inspect all valve seats and needles for wear, and replace worn piston or throat seals.