E-Flo SP Software Change History

The Version History of the E-Flo SP Software is listed below. The software currently installed on an E-Flo SP system can be found by navigating to Advanced Setup Screen four. Details on this screen can be found in E-Flo SP Software Manual 3A6724.

All E-Flo SP systems should match one of the following system versions.

If an upgrade to a newer software version is desired, follow the procedure in manual 3A6321 to download the latest version of software to a token.  Alternatively, order the appropriate “Software Upgrade Token” as listed below. This Upgrade Token is used to upgrade software on all of the system components per the procedure described in manual 3A1244.

NOTE: Upgrading software may clear some USB data (i.e. pump cycles, material volume, etc.)  It is recommended that a full USB download be completed before upgrading software.

DOWNLOAD LATEST SOFTWARE HERE:

Software Upgrade Token 17X094 Series L

  • System: 17X093l.gti (Software Link) version 1.10.005
  • Advanced Display: 17X078 Version 1.06.003
  • USB Configuration: 17X081 Version 1.02.001
  • Motor Control Module: 17X082 Version 1.10.004
  • Communications Gateway Module (CGM): 17P796 Version 3.01.004

Change History

  • Pressure sensor mV offsets changed to correct the incorrect pressure readings.
  • Flush Mount Transducer Installed check box added which changes the mV offset to accommodate for the change in transducer.
  • Load sharing added.
  • Start/stop button updated.

Software Upgrade Token 17X094 Series K

 

  • System: 17X093 version 1.09.002
  • Advanced Display: 17X078 Version 1.05.001
  • USB Configuration: 17X081 Version 1.01.001
  • Motor Control Module: 17X082 Version 1.09.003
  • Communications Gateway Module (CGM): 17P796 Version 3.01.004

Change History

  • Added drop down to select pump lower type on ADM.
  • When Elite Checkmate pump are selected, the maximum pressure is limited to 4200 psi.
  • Fixed bug that was introduced when outlet pressure transducer was moved away from the pump. This could cause the pump not to reach the desired pressure.
  • Fixed a bug where if the pump is calibrated and ends up being a negative pressure, after the first changeover the flowrate would max out and not come back down.
  • Fixed bug that would cause reset on the ADM setup screen when six pumps where online

Software Upgrade Token 17X094 Series J.

  • System: 17X093j version 1.06.003
  • Advanced Display: 17X078 Version 1.03.003
  • USB Configuration: 17X081 Version 1.01.001
  • Motor Control Module: 17X082 Version 1.07.001
  • Communications Gateway Module (CGM): 17P796 Version 3.01.004

Change History

  • Added new feature that when the automation mode is in discrete, and the discrete display control is checked, the pump will use the display information to control the pump when the discrete system enable pin is high.

Software Upgrade Token 17X094 Series H.

System: 17X093h  version 1.05.002

Advanced Display: 17X078 Version 1.02.001

USB Configuration: 17X081 Version 1.01.001

Motor Control Module: 17X082 Version 1.06.001

Communications Gateway Module (CGM): 17P796 Version 3.01.004

Change History

  • Updated EEPROM Library for new chip size.

Software Upgrade Token 17X094 Series G.

System: 17X093g version 1.05.001

Advanced Display: 17X078 Version 1.02.001

USB Configuration: 17X081 Version 1.01.001

Motor Control Module: 17X082 Version 1.05.001

Communications Gateway Module (CGM): 17P796 Version 3.01.004

Change History

  • Updated the pressure control algorithm to reduce the pressure overshoot that can occur when the pump is stalled.
  • Addresses a bug that was introduced into version 1.04.003 that would cause a WMN_ error shortly after powering on.

Software Upgrade Token 17X094 Series F.

System: 17X093f version 1.04.003

Advanced Display: 17X078 Version 1.02.001

USB Configuration: 17X081 Version 1.01.001

Motor Control Module: 17X082 Version 1.04.003

Communications Gateway Module (CGM): 17P796 Version 3.01.004

Change History

  • Added additional criteria for setting the system ready pin state within the discrete IO driver interface.

 

Software Upgrade Token 17X094 Series E.

 

System: 17X093 version 1.04.002

Advanced Display: 17X078 Version 1.02.001

USB Configuration: 17X081 Version 1.01.001

Motor Control Module: 17X082 Version 1.04.002

Communications Gateway Module (CGM): 17P796 Version 3.01.004

Change History

  • Addressed an issue where, over time, the pump cycle count, platen cycle count, and remaining drum volume could be reset when power is cycled.
  • For ram and tandem systems, pump priming now operates in open loop pressure control mode.  This allows for the pump to be primed even if the outlet pressure transducer readings exceed the specified prime pressure.

Software Upgrade Token: 17X094 Series D.

System: 17X093 version 1.03.001

Advanced Display: 17X078 Version 1.02.001

USB Configuration: 17X081 Version 1.01.001

Motor Control Module: 17X082 Version 1.03.001

Communications Gateway Module (CGM): 17P796 Version 3.01.004

Change History

  • For Tandem systems only, a pump crossover would sometimes occur when power was removed from the entire system while the system was enabled.
  • Inconsistent operation of the cancel key in certain system setup screens.
  • Within the system setup screen, changing both the system type and the assigned zones of pumps could cause only some of the changes to apply.

Software Upgrade Token: 17X094 Series C.

System: 17X093 version 1.02.001

Advanced Display: 17X078 Version 1.01.002

USB Configuration: 17X081 Version 1.01.001

Motor Control Module: 17X082 Version 1.02.001

Communications Gateway Module (CGM): 17P796 Version 3.01.004

Change History

Improved pressure and flow rate performance during pump changeovers.

 

Software Upgrade Token: 17X094 Series A.

  • System: 17X093 version 1.01.001
  • Advanced Display: 17X078 Version 1.01.002
  • USB Configuration: 17X081 Version 1.01.001
  • Motor Control Module: 17X082 Version 1.01.001
  • Communications Gateway Module (CGM): 17P796 Version 3.01.004

Change History

Initial Release.