The Version History of Fluid Automation F4 software is listed below. The software currently installed on the F4 system can be found by navigating to Advanced Screen 4.
All F4 systems should match one of the following system versions.
To upgrade to a newer software version, order the appropriate “Software Upgrade Token” as listed below.
Please refer to the maintenance section of the Software Update Procedure manual (335028) for instructions on how to upgrade the modules.
Software Upgrade Token Kit 17C706 Series G
Software Upgrade Token Kit 17C706 Series G
Software Upgrade Token Kit 17C706 (Series F)
Advanced Display: 17C699 version 1.03.005
USB Configuration: 17C702 version 1.02.001
FCM #1: 17C703 version 1.03.005
FCM#2: 17C704 version 1.03.005
1. Changed the variable ratio limits Max is 1.51 and Min is 0.66
Software Upgrade Token Kit 17C706 (Series E)
Advanced Display: 17C699 version 1.03.003
USB Configuration: 17C702 version 1.02.001
FCM #1: 17C703 version 1.03.003
FCM #2: 17C704 version 1.03.003
1. Small Shot Mode
a) A specialized mode to allow smaller dispense sizes to be taken with the F4 machine. Requires:
i. Two additional pressure sensors.
ii. A Blue Token to enable this feature.
2. Ratio Adjustment
a) New feature to allow the adjustment of the A:B Ratio in the range of [0.8:1 to 1.2:1]
b) Alternatively, ratio offset may also be changed by Percentage of A used. Similar to format on FAI’s M4 user interface.
c) Ratio target is now added as a column in USB logs.
d) Ratio Adjustment is also displayed in percentages of each material’s usage.
3. Pressure Unit Adjustment
a) Optional pressure sensors, unit may be selected for psi, bar, MPa
Software Upgrade Token Kit 17C706 (Series D)
Advanced Display: 17C699 version 1.02.001
USB Configuration: 17C702 version 1.01.005
FCM #1: 17C703 version 1.02.001
FCM#2: 17C704 version 1.02.001
Software Upgrade Token Kit 17C706 (Series C) (Obsolete)
Advanced Display: 17C699 version 1.01.002
USB Configuration: 17C702 version 1.01.001
FCM #1: 17C703 version 1.01.002
FCM #2: 17C704 version 1.01.002
Software Upgrade Token Kit 17C706 (Series B) (Obsolete)
Advanced Display: 17C699 version 1.01.001
USB Configuration: 17C702 version 1.01.001
FCM #1: 17C703 version 1.01.001
FCM #2: 17C704 version 1.01.001
Initial Release
See instruction manual 332453 for complete details on the Graco ExactaBlend AGP System. The latest revision manual can be found at www.Graco.com.
Read, understand and follow all instruction manuals and warning labels supplied with all equipment. Only trained and qualified personnel should perform repairs on the equipment. To access the latest manuals in your preferred language go to "www.Graco.com" and use the "Search" function.