Therm-O-Flow Software Change History

The Version History of Therm-O-Flow software is listed below. The software currently installed on a Therm-O-Flow system can be found by navigating to Advanced Setup Screen 4.  To view the software part numbers of the system, press the “ Magnifying Glass ” soft key option, as indicated below.

To upgrade to a newer software version, order the latest Software Upgrade Token listed below. Please refer to the maintenance section of the Therm-O-Flow instruction manual for instructions on how to upgrade the modules. Reference Therm-O-Flow instruction manual: 334130

NOTE: Upgrading software may clear some USB data (i.e. pump cycles, material volume, etc.)  It is recommended that a full USB download be completed before upgrading software.

 

For PLC and CGM related Fieldbus and other important integration files Click Here

Software Upgrade Token 17C712 Series ZAK

  • System 17C050zak (Software Link) Version 1.06.003
  • Advanced Display: 17C044 version 1.06.003
  • USB Control Module: 17C049  version 1.02.002
  • CGM Gateway Module: 17P796  version 3.01.009
  • Low Power Multi-Zone Temp. Control Module: 16T936 version 1.08.007
  • Automatic Wiring Board (AWB): 16W672 version 1.04.005
  • Modified "slow" default settings to prevent overshoot and allow for a faster speed up time.
  • Miscellaneous bug fixes.

Software Upgrade Token 17C712 Series ZAJ

  • System 17C050zaj (Software Link) Version 1.04.045
  • Advanced Display: 17C044 version 1.04.045
  • USB Control Module: 17C049  version 1.02.002
  • CGM Gateway Module: 17P796  version 3.01.004
  • Low Power Multi-Zone Temp. Control Module: 16T936 version 1.08.007
  • Automatic Wiring Board (AWB): 16W672 version 1.04.005
  • ADM response time improved.
  • On tandem systems, the secondary pump's icon has been changed to a prime icon.
  • Crossover events are logged correctly instead of as setup values.

Software Upgrade Token 17C712 Series ZAC

  • System 17C050zac Version 1.04.045
  • Advanced Display: 17C044 version 1.04.045
  • USB Control Module: 17C049  version 1.02.002
  • CGM Gateway Module: 17P796  version 3.01.004
  • Low Power Multi-Zone Temp. Control Module: 16T936 version 1.08.007
  • Automatic Wiring Board (AWB): 16W672 version 1.04.005
  • Feature added for a PLC add on kit.

Software Upgrade Token 17C712 Series ZAB

  • System 17C050 Version 1.04.042
  • Advanced Display: 17C044 version 1.04.042
  • USB Control Module: 17C049  version 1.02.002
  • CGM Gateway Module: 17P796  version 3.01.004
  • Low Power Multi-Zone Temp. Control Module: 16T936 version 1.08.007
  • Automatic Wiring Board (AWB): 16W672 version 1.04.005
  • General improvements to TOF Mini-5 systems (Non-heated pump detection and ADM Interface).
  • System will default to “Normal” heat rates on initial setup
  • Fixed a potential issue with Version X that could corrupt an MZLP on initial configuration.

Software Upgrade Token 17C712 Series X

  • System 17C050 Version 1.04.030
  • Advanced Display: 17C044 version 1.04.030
  • USB Control Module: 17C049  version 1.02.002
  • CGM Gateway Module: 17P796  version 3.01.004
  • Low Power Multi-Zone Temp. Control Module: 16T936 version 1.08.007
  • Automatic Wiring Board (AWB): 16W672 version 1.04.005
  • Fixed some issues concerning the Mini version of the TOF product, which is typically installed without a pump heater zone.
  • Fixed an intermittent issue where the system would reset during the Token software update process.
  • Modified the Advanced #4 setup screen to have the capability to program a black token using the ADM module and an USB stick..

Software Upgrade Token 17C712 Series V

  • Advanced Display: 17C044 version 1.04.019
  • USB Control Module: 17C049  version 1.02.002
  • CGM Gateway Module: 17P796  version 3.01.004
  • Low Power Multi-Zone Temp. Control Module: 16T936 version 1.08.007
  • Automatic Wiring Board (AWB): 16W672 version 1.04.005
  • Corrected pump inactivity logic to only modify unloaders that are not off.  Prior to this, the pump inactivity timers would bring both units into setback mode when it expired; regardless of if the secondary unloader was on or off.  The secondary unloader would warm up to setback if the timer expired and the unit was off.
  • Modified the stack light to turn solid red when one or both of the drums in a tandem unit are empty - previously it was flashing red.

Software Upgrade Token 17C712 Series T

  • Advanced Display: 17C044 version 1.04.010
  • USB Control Module: 17C049  version 1.02.002
  • CGM Gateway Module: 17P796  version 3.01.004
  • Low Power Multi-Zone Temp. Control Module: 16T936 version 1.08.007
  • Automatic Wiring Board (AWB): 16W672 version 1.04.005
  • Corrected issue where pressing the red key in quick succession would reset the ADM.
  • Corrected issue where entering warning and alarm offsets in degrees F would be rejected.  The work around was setting them in degrees C.

Software Upgrade Token: 17C712 Series S

  • Advanced Display: 17C044 version 1.04.007
  • USB Control Module: 17C049  version 1.02.002
  • CGM Gateway Module: 17P796  version 3.01.004
  • Low Power Multi-Zone Temp. Control Module: 16T936 version 1.08.007
  • Automatic Wiring Board (AWB): 16W672 version 1.04.005
  • Corrected issue associated with setting minimum temperature delta alarms.  Minimum defaulted to 12C when it should be 11C.  

Software Upgrade Token: 17C712 Series R

  • Advanced Display: 17C044 version 1.04.006
  • USB Control Module: 17C049  version 1.02.002
  • CGM Gateway Module: 17P796  version 3.01.004
  • Low Power Multi-Zone Temp. Control Module: 16T936 version 1.08.007
  • Automatic Wiring Board (AWB): 16W672 version 1.04.005
  • Corrected issue that could cause nuisance alarms associated with the Platen Zone.
  • Corrected issue that could cause a user to have to cycle power on the machine in the event of an alarm with the platen.

Software Upgrade Token: 17C712 Series P

  • Advanced Display: 17C044 version 1.03.079
  • USB Control Module: 17C049  version 1.02.002
  • CGM Gateway Module: 17P796  version 3.01.004
  • Low Power Multi-Zone Temp. Control Module: 16T936 version 1.08.007
  • Automatic Wiring Board (AWB): 16W672 version 1.04.005
  • AWB Alarms for A & B were both reading from AWB A.  Issue corrected to report alarms from both AWBs.
  • Corrected occasional nuisance alarms that would occur for the platen zone when coming out of setback.
  • Corrected "rejection beep" generation on System Screen 2 for Alarm & Warning Setpoints.
  • Addressed Min/Max value suggestions for Alarm & Warning Setpoints on System Screen 2.
  • Fixed an issue where the secondary unit would not follow primary unit out of setback when the primary drum was low.

Software Upgrade Token 17C712 Series N

  • Advanced Display: 17C044 version 1.03.068
  • USB Control Module: 17C049  version 1.02.002
  • CGM Gateway Module: 17P796  version 3.01.004
  • Low Power Multi-Zone Temp. Control Module: 16T936 version 1.08.007
  • Automatic Wiring Board (AWB): 16W672 version 1.04.005
  • Cleaned up some of the ADM logic (17C044), which would intermittently generate fault errors during the heating warm-up process.
  • Created a custom version of the ADM logic (P/N: U82757) for a large customer of the TOF product. 
  • Added an item to the Data Exchange portion of the CGM interface, to enable the controlling logic to obtain the version # of the ADM.  Also added logic to enable the controlling logic to obtain the Control variable (duty cycle %) for the selected zone on the CGM Data Exchange interface.

Software Upgrade Token 17C712 Series M

  • Advanced Display: 17C044 version 1.03.033
  • USB Control Module: 17C049  version 1.02.002
  • CGM Gateway Module: 17P796  version 3.01.004
  • Temperature Control Module: 16T936 version 1.08.007
  • Automatic Wiring Board (AWB): 16W672 version 1.04.005
  • Added logic to ADM to allow CGM control and/or data monitoring of the TOF system. 
  • Added CGM logic to software BOM.
  • Added a “Heat Rate Option” Control to the Advanced #2 setup screen, to allow the user to select between normal (default), fast and slow heat buildup selections.
  • Changed ADM logic to NOT output “---“ for to zone actual temperatures when the temperature exceeds 204 C (400 F).
  • Changed ADM logic to transition out of the warm up state when the last zone is within 1.5% of its target temperature, rather than 1 %..  

Software Upgrade Token: 17C712 Series L

  • Advanced Display: 17C045 version 1.03.007
  • USB Control Module: 17C049 version 1.02.001
  • Temperature Control Module: 16T936 version 1.08.007
  • Automatic Wiring Board (AWB): 16W672 version 1.04.005
  • Added a pump prime timer to the ADM when in PLC or External Control mode.
  • Timer is user-settable on Advanced System Screen 2.
  • PLC & External Control Mode: A gun trigger turns on the active unloader's pump; a PLC input turns on the corresponding A or B unloader's pump.
  • Added more substantial arrows to the reset screen animation when toggling between tandem and single systems.
  • Added new icons to the system screen to show when the softkeys will be using a timer.

Software Upgrade Token: 17C712 Series K

  • Advanced Display: 17C045 version 1.03.003
  • USB Control Module: 17C049 version 1.02.001
  • Temperature Control Module: 16T936 version 1.08.007
  • Automatic Wiring Board (AWB): 16W672 version 1.03.003
  • This version addresses issues with the current that CR-1 is allowed to draw.

Software Upgrade Token: 17C712 Series J

  • Advanced Display: 17C045 version 1.03.003
  • USB Control Module: 17C049 version 1.02.001
  • Temperature Control Module: 16T936 version 1.08.005
  • Automatic Wiring Board (AWB): 16W672 version 1.03.003
  • This version addresses issues with distributing power to the MZLPs on UnitB in a Tandem system.
  • It also increases the power availability to the MZLPs during warmup and running. Additionally, the extra power allocated for warmup carries into the Heatsoak state since we could still be warming up material inside of the heated devices.

Software Upgrade Token: 17C712 Series H

  • Advanced Display: 17C045 version 1.02.006
  • USB Control Module: 17C049 version 1.02.001
  • Temperature Control Module: 16T936 version 1.08.005
  • Automatic Wiring Board (AWB): 16W672 version 1.03.003
  • Updates made to allow priming of secondary unit on a tandem system. Changes made to the graphics end of the System Run Screen to eliminate flickering. Fixed an issue with external pump control using PLC inputs.

Software Upgrade Token: 17C712 Series G

  • Advanced Display: 17C045 version 1.02.005
  • USB Control Module: 17C049 version 1.02.001
  • Temperature Control Module: 16T936 version 1.08.005
  • Automatic Wiring Board (AWB): 16W672 version 1.03.003
  • Added feature to allow the User to use the enable pump control Customer IO pin 3 while the check box for enable external pump control is checked. 
  • Modified tandem w/external trigger systems to allow secondary unit to prime using the "pump" button. Changed graphics side to show when external trigger is being used/pump is on.

Software Upgrade Token: 17C712 Series F

  • Advanced Display: 17C045 version 1.02.002
  • USB Control Module: 17C049 version 1.02.001
  • Temperature Control Module: 16T936 version 1.07.001
  • Automatic Wiring Board (AWB): 16W672 version 1.03.003
  • Uses High Temp Alarms & Warnings defined by the user in the advanced screens for setback now too, instead of internally defined values.

Software Upgrade Token: 17C712 Series E

  • Advanced Display: 17C045 version 1.02.001
  • USB Control Module: 17C049 version 1.02.001
  • Temperature Control Module: 16T936 version 1.07.001
  • Automatic Wiring Board (AWB): 16W672 version 1.03.003
  • Changed how the pump inactivity timer looks at a tandem system. (Example: the pump inactivity timer only looked at the primary unit so if the secondary unit is active the timer did not see it and will put the system to setback and then system off.)  

Software Upgrade Token: 17C712 Series D

  • Advanced Display: 17C045 version 1.01.002
  • USB Control Module: 17C049 version 1.01.021
  • Temperature Control Module: 16T936 version 1.07.001
  • Automatic Wiring Board (AWB): 16W672 version 1.03.003
  • Changed scaling in diagnostic logs so the incoming voltages are logged properly from the AWB. 
  • Changed diagnostic logs to show all leg-to-leg voltages 
  • Fixed Unit B's offset on the diagnostic log for AWB voltages. Unit A was recorded twice. 
  • Revised USB Build to delete old USB data 
  • Relaxed gun trigger to look at all trigger zones, even if they aren't enabled per customer feedback.
  • Added function calls to ADM Primary portal to see what the peak voltage range the unit experienced was, and how long it spent there. 

Software Upgrade Token: 17C712 Series C

  • Advanced Display: 17C045 version 1.01.001
  • USB Control Module: 17C049 version 1.00.001
  • Temperature Control Module: 16T936 version 1.04.001
  • Automatic Wiring Board (AWB): 16W672 version 1.02.008
  • User Defined Runaway Added 
  • USB Logs Modified 

Software Upgrade Token: 17C712 Series B

  • Advanced Display: 17C045 version 1.00.001
  • USB Control Module: 17C049 version 1.00.000
  • Temperature Control Module: 16T936 version 1.04.001
  • Automatic Wiring Board (AWB): 16W672 version 1.02.008
  • MZLP indexing changed on secondary from 4,5,6 to 5,6,7 for UL499 Compliance. 
  • Secondary Customer IO matches Primary now 
  • Both pumps can run at the same time on a tandem to double output now. 
  • USB Data Logger Units Fixed 
  • Changed default weight to LBS 
  • Diagnostic Screen No Longer Enabled By Default. 
  • Changed Default Heatsoak to 45 minutes.  

Software Upgrade Token: 17C712 Series A

  • Advanced Display: 17C045 version 0.00.000
  • USB Control Module: 17C049 version 0.00.000
  • Temperature Control Module: 16T936 version 1.04.001
  • Automatic Wiring Board (AWB): 16W672 version 1.01.003
  • Initial Release.  

Read, understand and follow all instruction manuals and warning labels supplied with all equipment.  Only trained and qualified personnel should perform repairs on the equipment.  To access the latest manuals in your preferred language go to "www.Graco.com" and use the "Search" function.