VRM and VPM Software Change History

The Version History of VRM and VPM software is listed below. The software currently installed on a VRM or VPM system can be found by navigating to Advanced Setup Screen 5. All VRM and VPM systems should match one of the following system versions.

To upgrade to a newer software version, order the appropriate "Software Upgrade Token" as listed below. This Upgrade Token is used to upgrade software on all of the system components per the procedure described in the Maintenance section of the instruction manual 313875 for VPM or 313873 for VRM.

This token does not upgrade any accessory add-on features like ratio monitoring, tank stands, communication or discrete gateway modules. Please see the appropriate Product Knowledge Exchange (PKE) for the accessory desired to see the software revision history and upgrade token for it.

Software Upgrade Token: 16G365 Series T

Advanced Display (ADM): 16P573 version 1.02.037

Motor Control Module (MCM): 16E851 version 1.06.005

USB Configuration: 16P575 version 1.01.007

Temperature Control Module: 15M871 version 1.07.005

ADM - Added 100:xx Ratio Capability, Off Ratio Time to Fault Override User Entry, and Ratio Monitoring Supervisory logic to ensure an un-alarmed Off ratio dispense does not occur.

USB - Added 100:xx ratio output capability, Removed Applicator # Column, corrected an error logging issue.

MCM - Added logic to support the new Off Ratio Time to Fault Override feature.

Software Upgrade Token: 16G365 Series S (no longer available for sale)

Advanced Display: 16P573 version 1.02.007

Motor Control Module: 16E851 version 1.06.004

USB Configuration: 16P575 version 1.01.001

Temperature Control Module: 15M871 version 1.07.005

Advanced Display and Motor Control Modules, Items added:

  1. DataStore Library updated to prevent problems found with the HFR Product.

  2. Material Counters Improved to:

  • Allow roller-over from maximum value (4.x billion) to 0 if the situation occurs.
  • Saved counter information to EE2 memory every 1 minute, to account if power interrupted during a very long dispense operation.

Long Dispense Flow Adjust Feature released

Software Upgrade Token: 16G365 Series R (no longer available for sale)

Advanced Display: 16P573 version 1.02.004

Motor Control Module: 16E851 version 1.05.012

USB Configuration: 16P575 version 1.01.001

Temperature Control Module: 15M871 version 1.07.005

Communication Gateway Module (CGM): 15U193 version 2.06.004

Change made to fix issues with CGM Ethernet IP fieldbus renaming issues

Software Upgrade Token: 16G365 Series P (no longer available for sale)

Advanced Display: 16P573 version 1.02.004

Motor Control Module: 16E851 version 1.05.012

USB Configuration: 16P575 version 1.01.001

Temperature Control Module: 15M871 version 1.07.005

Communication Gateway Module (CGM): 15U193 version 2.06.003

CGM - Fixed issue where the Node label would make corresponding CGM act erratic when viewing the ADM, if changed.

Software Upgrade Token: 16G365 Series M (no longer available for sale)

Advanced Display: 16P573 version 1.02.004

Motor Control Module: 16E851 version 1.05.012

USB Configuration: 16P575 version 1.01.001

Temperature Control Module: 15M871 version 1.07.005

Advanced Display Module and Motor Control Module - Added capability to disable ratio &/or flow rate changes during an active operator mode dispense from the main run screen. Added capability to "remember" reverse parameters after a power cycle, to better enable the VPM machine to maintain ratio for the 1st few dispenses after boot up.

Software Upgrade Token: 16G365 Series L (no longer available for sale)

Advanced Display: 16P573 version 1.01.002

Motor Control Module: 16E851 version 1.05.010

USB Configuration: 16P575 version 1.01.001

Temperature Control Module: 15M871 version 1.07.005

Advanced Display Module and Motor Control Module - Created all new part numbers for Advanced Display Module, to make it NOT the same as the HFR product. Modified Motor Control Module logic to not stop pump during a cavitation condition, if the material is being dispensed out of ratio check valves.

Software Upgrade Token: 16G365 Series H (no longer available for sale)

Advanced Display: 16E122 version 1.10.012

Motor Control Module: 16E851 version 1.05.007

USB Configuration: 16G102 version 1.07.001

Temperature Control Module: 15M871 version 1.07.005

Fluid Control Module: 16A039 version 1.05.069

16E122 - Fixed a bug documented in bug # 6659, where the Advanced Display Module would not generate some errors derived from the Red pump Motor Control Module. Added control enhancement to the Motor Control Module logic.

15M871 - Issues addressed pertaining to features used by the Diesel reactor project. This change does not affect this product at all.

Software Upgrade Token: 16G365 Series G (no longer available for sale)

Advanced Display: 16E122 version 1.09.165

Motor Control Module: 16E851 version 1.05.005

USB Configuration: 16G102 version 1.07.001

Temperature Control Module: 15M871 version 1.06.001

Fluid Control Module: 16A039 version 1.05.069

16E122, 16E851 Added capability to calibrate or use the machine without the need for Flow meters installed.

Software Upgrade Token: 16G365 Series F (no longer available for sale)

Advanced Display: 16E122 version 1.07.001

Motor Control Module: 16E851 version 1.04.005

USB Configuration: 16G102 version 1.05.002

Temperature Control Module: 15M871 version 1.06.001

Fluid Control Module: 16A039 version 1.04.001

16E122 Added temperature monitoring zones; user selectable ratio BLUE:RED or RED:BLUE

16E851 Enhanced pump synchronization

Software Upgrade Token: 16G365 Series E (no longer available for sale)

Advanced Display: 16E122 version 1.06.001

Motor Control Module: 16E851 version 1.04.002

USB Configuration: 16G102 version 1.05.002

Temperature Control Module: 15M871 version 1.06.001

Fluid Control Module: 16A039 version 1.04.001

16E122 No change made

16E851 Added Communications Gateway Module off-line detection

15M871 update for above temperature alarm error

16A039 Support for Prime mode added

16G102 Updated logs in the USB configuration

Software Upgrade Token: 16G365 Series D (no longer available for sale)

Advanced Display: 16E122 version 1.04.004

Motor Control Module: 16E851 version 1.03.001

USB Configuration: 16G102 version 1.05.001

Temperature Control Module: 15M871 version 1.05.006

Fluid Control Module: 16A039 version 1.03.001

16E122 Support for high temperature level sensors, if installed, temperatures can be set to 190F or 88C

16E851 improved the pump synchronization logic

16A039 Support for Variable Ratio systems added

Software Upgrade Token: 16G365 Series C (no longer available for sale)

Advanced Display: 16E122 version 1.04.004

Motor Control Module: 16E851 version 1.03.001

USB Configuration: 16G102 version 1.05.001

Temperature Control Module: 15M871 version 1.05.006

Fluid Control Module: 16A039 version 1.01.004

16E122 updated screens for variable ratio; updated component code

16E851 Increased robustness of ramping logic

Software Upgrade Token: 16G365 Series B (no longer available for sale)

Advanced Display: 16E122 version 1.04.001

Motor Control Module: 16E851 version 1.02.001

USB Configuration: 16G102 version 1.05.001

Temperature Control Module: 15M871 version 1.05.006

Fluid Control Module: 16A039 version 1.01.004

16E122 Reworked screens for variable ratio

16E851 Added Ramping Logic

Software Upgrade Token: 16G365 Series A (no longer available for sale)

Advanced Display: 16E122 version 1.01.001

Motor Control Module: 16E851 version 1.03.001

USB Configuration: 16G102 version 1.01.001

Temperature Control Module: 15M871 version 1.05.006

Fluid Control Module: 16A039 version 1.01.004

Initial Release

See the appropriate instruction manual: 313875 for VPM or 313873 for VRM complete details on the Graco VRM or VPM Metering Systems. The latest revision manual can be found at www.graco.com.

Read, understand and follow all instruction manuals and warning labels supplied with all equipment. Only trained and qualified personnel should perform repairs on the equipment. To access the latest manuals in your preferred language go to "www.Graco.com" and use the "Search" function.