The Version History of VRM and VPM software is listed below. The software currently installed on a VRM or VPM system can be found by navigating to Advanced Setup Screen 5. All VRM and VPM systems should match one of the following system versions.
To upgrade to a newer software version, order the appropriate "Software Upgrade Token" as listed below. This Upgrade Token is used to upgrade software on all of the system components per the procedure described in the Maintenance section of the instruction manual 313875 for VPM or 313873 for VRM.
This token does not upgrade any accessory add-on features like ratio monitoring, tank stands, communication or discrete gateway modules. Please see the appropriate Product Knowledge Exchange (PKE) for the accessory desired to see the software revision history and upgrade token for it.
Software Upgrade Token: 16G365 Series T
Advanced Display (ADM): 16P573 version 1.02.037
Motor Control Module (MCM): 16E851 version 1.06.005
USB Configuration: 16P575 version 1.01.007
Temperature Control Module: 15M871 version 1.07.005
ADM - Added 100:xx Ratio Capability, Off Ratio Time to Fault Override User Entry, and Ratio Monitoring Supervisory logic to ensure an un-alarmed Off ratio dispense does not occur.
USB - Added 100:xx ratio output capability, Removed Applicator # Column, corrected an error logging issue.
MCM - Added logic to support the new Off Ratio Time to Fault Override feature.
Software Upgrade Token: 16G365 Series S (no longer available for sale)
Advanced Display: 16P573 version 1.02.007
Motor Control Module: 16E851 version 1.06.004
USB Configuration: 16P575 version 1.01.001
Temperature Control Module: 15M871 version 1.07.005
Advanced Display and Motor Control Modules, Items added:
1. DataStore Library updated to prevent problems found with the HFR Product.
2. Material Counters Improved to:
Long Dispense Flow Adjust Feature released
Software Upgrade Token: 16G365 Series R (no longer available for sale)
Advanced Display: 16P573 version 1.02.004
Motor Control Module: 16E851 version 1.05.012
USB Configuration: 16P575 version 1.01.001
Temperature Control Module: 15M871 version 1.07.005
Communication Gateway Module (CGM): 15U193 version 2.06.004
Change made to fix issues with CGM Ethernet IP fieldbus renaming issues
Software Upgrade Token: 16G365 Series P (no longer available for sale)
Advanced Display: 16P573 version 1.02.004
Motor Control Module: 16E851 version 1.05.012
USB Configuration: 16P575 version 1.01.001
Temperature Control Module: 15M871 version 1.07.005
Communication Gateway Module (CGM): 15U193 version 2.06.003
CGM - Fixed issue where the Node label would make corresponding CGM act erratic when viewing the ADM, if changed.
Software Upgrade Token: 16G365 Series M (no longer available for sale)
Advanced Display: 16P573 version 1.02.004
Motor Control Module: 16E851 version 1.05.012
USB Configuration: 16P575 version 1.01.001
Temperature Control Module: 15M871 version 1.07.005
Advanced Display Module and Motor Control Module - Added capability to disable ratio &/or flow rate changes during an active operator mode dispense from the main run screen. Added capability to "remember" reverse parameters after a power cycle, to better enable the VPM machine to maintain ratio for the 1st few dispenses after boot up.
Software Upgrade Token: 16G365 Series L (no longer available for sale)
Advanced Display: 16P573 version 1.01.002
Motor Control Module: 16E851 version 1.05.010
USB Configuration: 16P575 version 1.01.001
Temperature Control Module: 15M871 version 1.07.005
Advanced Display Module and Motor Control Module - Created all new part numbers for Advanced Display Module, to make it NOT the same as the HFR product. Modified Motor Control Module logic to not stop pump during a cavitation condition, if the material is being dispensed out of ratio check valves.
Software Upgrade Token: 16G365 Series H (no longer available for sale)
Advanced Display: 16E122 version 1.10.012
Motor Control Module: 16E851 version 1.05.007
USB Configuration: 16G102 version 1.07.001
Temperature Control Module: 15M871 version 1.07.005
Fluid Control Module: 16A039 version 1.05.069
16E122 - Fixed a bug documented in bug # 6659, where the Advanced Display Module would not generate some errors derived from the Red pump Motor Control Module. Added control enhancement to the Motor Control Module logic.
15M871 - Issues addressed pertaining to features used by the Diesel reactor project. This change does not affect this product at all.
Software Upgrade Token: 16G365 Series G (no longer available for sale)
Advanced Display: 16E122 version 1.09.165
Motor Control Module: 16E851 version 1.05.005
USB Configuration: 16G102 version 1.07.001
Temperature Control Module: 15M871 version 1.06.001
Fluid Control Module: 16A039 version 1.05.069
16E122, 16E851 Added capability to calibrate or use the machine without the need for Flow meters installed.
Software Upgrade Token: 16G365 Series F (no longer available for sale)
Advanced Display: 16E122 version 1.07.001
Motor Control Module: 16E851 version 1.04.005
USB Configuration: 16G102 version 1.05.002
Temperature Control Module: 15M871 version 1.06.001
Fluid Control Module: 16A039 version 1.04.001
16E122 Added temperature monitoring zones; user selectable ratio BLUE:RED or RED:BLUE
16E851 Enhanced pump synchronization
Software Upgrade Token: 16G365 Series E (no longer available for sale)
Advanced Display: 16E122 version 1.06.001
Motor Control Module: 16E851 version 1.04.002
USB Configuration: 16G102 version 1.05.002
Temperature Control Module: 15M871 version 1.06.001
Fluid Control Module: 16A039 version 1.04.001
16E122 No change made
16E851 Added Communications Gateway Module off-line detection
15M871 update for above temperature alarm error
16A039 Support for Prime mode added
16G102 Updated logs in the USB configuration
Software Upgrade Token: 16G365 Series D (no longer available for sale)
Advanced Display: 16E122 version 1.04.004
Motor Control Module: 16E851 version 1.03.001
USB Configuration: 16G102 version 1.05.001
Temperature Control Module: 15M871 version 1.05.006
Fluid Control Module: 16A039 version 1.03.001
16E122 Support for high temperature level sensors, if installed, temperatures can be set to 190F or 88C
16E851 improved the pump synchronization logic
16A039 Support for Variable Ratio systems added
Software Upgrade Token: 16G365 Series C (no longer available for sale)
Advanced Display: 16E122 version 1.04.004
Motor Control Module: 16E851 version 1.03.001
USB Configuration: 16G102 version 1.05.001
Temperature Control Module: 15M871 version 1.05.006
Fluid Control Module: 16A039 version 1.01.004
16E122 updated screens for variable ratio; updated component code
16E851 Increased robustness of ramping logic
Software Upgrade Token: 16G365 Series B (no longer available for sale)
Advanced Display: 16E122 version 1.04.001
Motor Control Module: 16E851 version 1.02.001
USB Configuration: 16G102 version 1.05.001
Temperature Control Module: 15M871 version 1.05.006
Fluid Control Module: 16A039 version 1.01.004
16E122 Reworked screens for variable ratio
16E851 Added Ramping Logic
Software Upgrade Token: 16G365 Series A (no longer available for sale)
Advanced Display: 16E122 version 1.01.001
Motor Control Module: 16E851 version 1.03.001
USB Configuration: 16G102 version 1.01.001
Temperature Control Module: 15M871 version 1.05.006
Fluid Control Module: 16A039 version 1.01.004
Initial Release
See the appropriate instruction manual: 313875 for VPM or 313873 for VRM complete details on the Graco VRM or VPM Metering Systems. The latest revision manual can be found at www.graco.com.