E-6: Overdose B/A Dose too Short Alarm

To avoid serious injury follow all warnings and instructions in the manual. Wear appropriate personal protective equipment.

B dose overshoots and forces an A side dose that, when combined with B, is too large for the mix chamber capacity.

Tighten or replace valve.

 Check for pressure pulsations:

  1. Close all the manifold valves.
  2. Turn on the circulating pumps and all the booth equipment (such as fans and conveyors).
  3. Check if the ProMix 2KS is reading any fluid flow.
  4. If the ProMix 2KS shows there is fluid flow and there are no leaks from the gun or any other seals or fittings, the flow meters are probably being affected by pressure pulsations.
  5. Close the fluid shutoff valve between the fluid supply system and the flow meter. The flow indication should stop.
  6. If necessary, install pressure regulators or a surge tank on the fluid inlets to the ProMix 2KS to reduce the fluid supply pressure. Contact your Graco distributor for information.

See E-3: RATIO HIGH ALARM and E-4: RATIO LOW ALARM.

 It may be necessary to restrict the flow rate through the component B or C dose valve by adjusting its hex nut. See manual.