E2 : Low Ratio

To avoid serious injury follow all warnings and instructions in the manual. Wear appropriate personal protective equipment.

  • Verify that the A material pressure regulator is turned on and set to the correct pressure.
  • Verify the all ball valves before the applicator are open
  • Replace spray tip and while dispensing material monitor the display for A flow rate.
  • Verify that A side of gun is not plugged. Replace spray applicator and tips as necessary.
  • Inspect all cabling for proper connection and damage.
  • Verify A meter gears spin freely.     
  • If flow is registering, but at a reduced rate, inspect for A side of system for restrictions.
  • Verify that A side of gun is not restricted. Replace spray applicator and tips as necessary.
  • Inspect A hose for plugging.
  • Verify A material filters are not plugged.
  • Verify A meter gears spin freely.
  • Set material A pressure regulator to highest available pressure, but not above 200 psi (13.8 bar)
  • Material A pressure must be able to be about 50 psi (3.5 bar) above material B pressure.
  • Ensure material B pressure regulator is set at least 50 psi (3.5 bar) less than A pressure regulator.