P6BX : Pressure Sensor Error B
        
        
    
 
    
    
    
  
  
    To avoid serious injury follow all warnings and instructions in the manual. Wear appropriate personal protective equipment.
   
 
    
    
    
        
            
    
    
    
    
    
    - Check to ensure the pressure transducer is properly installed and all wires are properly connected.
 
 
         
     
 
    
    
        
            
    
    
    
    
    
    - Check if the error follows the transducer.  
- Disconnect transducer cables from the module (connectors 6 and 7).  
- Reverse A and B connections and check if the errors follows.  - If the error follows the transducer, replace the pressure transducer.
 
 
         
     
 
    
    
        
            
    
    
    
    
    
    - If both P6AX and P6BX error codes are triggered simultaneously, try disconnecting one pressure transducer at a time from the module.  
- If disconnecting one transducer clears both error codes and allows the opposite transducer to begin reading pressure, replace the disconnected pressure transducer.