T6NM : Sensor Error Motor

To avoid serious injury follow all warnings and instructions in the manual. Wear appropriate personal protective equipment.

  • Verify wiring between the motor temperature sensor and the module.

 

  • Measure resistance between pins 1 and 3 on motor temperature cable connector. Readings vary depending on temperature, but at room temperature (72°F/22°C), the resistance should be approximately 1500 to 2500 ohms. An open circuit reading indicates a possible wire break.  Replace motor.