To avoid serious injury follow all warnings and instructions in the manual. Wear appropriate personal protective equipment.
Disconnect power from the TPC and wait 5 minutes
Inspect the motor cable for damage.
Within the TPC, verify that the connectors on the motor cable are secured to the receptacles on the PCB. Verify that the wire ferrules are secured in the connectors.
Within the motor, verify that the motor power wires are properly connected to the motor cable power wires.
Within the TPC, disconnect the motor cable from the TPC. Check the phase-to-phase resistances of the motor. The resistance readings should be less than 3 ohms in each case.
Note: The conditions for this error are checked only on power up. To reset or re-check this error, cycle power to the entire Reactor system.