K8NB: MCM B Locked Rotor With Current

To avoid serious injury follow all warnings and instructions in the manual. Wear appropriate personal protective equipment.

  • Ensure transducer is not getting bad reading and is able to read pressures.
  • Repair or replace chemical pump.
  • Check pump gear trains for damage and repair or replace as necessary.
  • Remove pump gear housings from motor and check that motor shaft rotates freely in direction indicated on motor housing.
  • Make sure transducer is plumbed into fluid path at recirculation manifold.